L_TS2P_SyncAndCorrection: Mark error detection not correct for touch probe within correction window (corrected from V3.24.0)

Corrected from:
Library: L_TS2P_TechModulesSynchronizingCamming (from V03.24.00)
             (Update via EASY Package Manager)

Response of the new version:
The mark error is calculated correctly for a newly appearing mark. A previous mark error that has just been corrected is also taken into account.

What happens?
A part of an already recorded mark error is not taken into account when calculating the mark error. This leads to the original error being corrected again.

When does the behaviour occur?
If the TM SyncAndCorrection detects a touch probe within the correction window, this error can only be corrected when entering the next correction window.
Within the next correction window, the second touchprobe now occurs.

Expected behaviour:
A correction value still to be extended from a previous mark is taken into account when calculating the new mark error.

Which products are affected?
L_TS2P_SyncAndCorrectionState from the library L_TS2P_TechModulesSynchronizingCamming

Short-term measures:
Parameterise the application so that marks do not appear within the correction window.

Evaluation / recommendations:

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202100293/1/