L_TF2P_TablePositioning: Movement stops with falling edge (corrected from V3.24.0)

Corrected from:
Library: L_TF2P_TechModulesFollowingPositioning (from V03.24.00)
              (Update via EASY Package Manager)

Response of the new version:
During profile chaining, xExecutePOsitioning = TRUE->FALSE does not stop, but maintains the profile chaining.

What happens?
During profile chaining, the TM does not switch to the next chained profile, but the current profile is completed and then the TM switches to the "Standby" state.

When does the behaviour occur?
During an active profile chaining, the input xExecutePositioning is reset.

Expected behaviour:
Profiles continue to be driven off.

Which products are affected?
Technologie-Modul TablePositioning (L_TF2P_TablePositioningBase from library L_TF2P_TechModulesFollowingPositioning)

Short-term measures:
Leave input xExecutePositioning permanently TRUE for chained profiles.

Evaluation / recommendations: