L_TS2P_SyncAndCorrection: Position jump at scPar.xCalcMarkError (corrected from V3.24.0)

Corrected from:
Library: L_TS2P_TechModulesSynchronizingCamming (from  V03.24.00)
             (Update via EASY Package Manager)

Response of the new version:
Switching the technology mode from position synchronisation to register control is only possible in the disengaged state.

What happens?
A jump in position occurs.

When does the behaviour occur?
The behaviour occurs when switching back and forth between register control and position synchronisation during the engaged state.
This is done with the help of the parameter scPar.xCalcMarkErrorMaster.

Which products are affected?
L_TS2P_SyncAndCorrectionBase from library L_TS2PTechMoulesSynchronizingCamming

Short-term measures:
Change of operating mode only in disengaged state.

Evaluation / recommendations:

Automatic Translation