L_TF2P_TablePositioning: State "FINISHPOSITIONING" is not displayed (corrected from V3.24.0)

Corrected from:
L_TF2P_TechModulesFollowingPositioning (from V3.24.0)
(Update via Easy Package Manager)

Behaviour of new version:
With scCtrlBasicMotion.xFinishPositioning = TRUE the aborted profile is finished.
- The TM switches to the FINISHPOSITIONING state.
- The FINISHPOSITIONING state is exited when the position is reached or another function is activated.

What happens?
If an aborted positioning is continued, the technology module displays an incorrect state at the "eTMState" output. It depends on the level of the "xAbort" input:
- xAbort = TRUE, eTMState = STOP
- xAbort = FALSE, eTMState = STANDBY
 
When does the behaviour occur?
The behaviour occurs when an aborted positioning is continued (Finish Positioning): scCtrlBasicMotion.xFinishPositioning = TRUE.
 
Which products are affected?
Technology module TablePositioning (L_TF2P_TablePositioningBase from library L_TF2P_TechModulesFollowingPositioning)

Short-term measures:
-

Evaluation / recommendations:
-

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202100083/1/
Kontaktformular