L_TS2P_SyncAndCorrection: No warning appears after failure of the maximum allowed marks (ToolCorrection) (fixed as of V3.23.0)

Corrected from:
Firmware i950: 1.6 (Update via EasyPackageManager or Firmware Loader)
Library: L_TS2P_TechModulesSynchronizingCamming V3.23.0.20 (Update via Easy Package Manager)

Response of the new version:
The warning "MaxMissedMarks" is issued when the maximum number of allowed mark failures has occurred.

What happens?
The technology module does not issue a warning.

When does the behaviour occur?
The tool offset is used.
The marker window of the tool offset is activated.
More marks fail than the maximum allowed.

Which products are affected?
L_TS2P_SyncAndCorrectionState from the library L_TS2P_TechModulesSynchronizingCamming  
i950 Servo Inverter with TA SyncAndCorrection

Short-term measures:
None