L_TW2P_Winder: Measuring points of the material counter do not supply values (fixed from V3.20.0)

Corrected from:
L_TW2P_TechModulesWindingTraversing as of V03.20.00.33
 (Update via Package Manager)
 

Response of the new version? 
The measuring points mentioned provide valid values.

MP_liRevCounter
MP_lrRevCounterResidual   

 
What happens?
The measuring points mentioned from the calculation of the diameter do not provide any values.

 

When does the behavior occur?
The following measuring points from the scSignalFlow structure are used:

MP_liRevCounter
MP_lrRevCounterResidual
 

Which products are affected?
Function module L_TW2P_WinderTension/DancerCtrlState in library L_TW2P_TechModulesWindingTraversing v 3.19.0.22
 
Short-term measures:
The status information for calculating the diameter can also be read from the persistent data of the TM (structure PersistentVar).
 
Evaluation/Recommendations:
The measuring points are intended for the plausibility check of the diameter calculation. This does not affect the diameter calculation function. The information for the diameter calculation can be read from the persistent data taking into account the short-term measures.

 