L_TT1P_RegisterControlState, L_TT1P_CrossCutter: xMarkReceived is not set (corrected from V3.16.0)

Corrected from:
L_TT1P_RegisterControlState technology module from the L_TT1P_TechnologyModules_LM library (V3.16.0.62 and higher)
L_TT1P_CrossCutterState technology module from the L_TT1P_TechnologyModules_LM library (V3.16.0.62 and higher)
 
Response of the new version:
The xMarkReceived TM output is set.
 
What happens?
The xMarkReceived TM output is not set.
  
When does this behaviour occur?
The behaviour occurs if the RegisterControl or the CrossCutter technology module is used with touch probe marks.
 
Which products are affected?
L_TT1P_RegisterControlState technology module from the L_TT1P_TechnologyModules_LM library (V3.15.0.32 and higher)
L_TT1P_CrossCutterState technology module from the L_TT1P_TechnologyModules_LM library (V3.15.0.32 and higher)
 
Short-term measures:
None
 
Evaluation/recommendations:
The function restriction does not affect the L_TT1P_RegisterControlBase technology module.