L_TT1P_TablePositioning: Axis sporadically performs an additional revolution in the Relative_TP mode (eliminated from V3.16.0)

Eliminated from:
L_TT1P_TechnologyModules_LM (ab V3.16.0.62)
 
Behaviour of new version:
The axis correctly executes the specified relative movement after the touch-probe has occurred.
 
 
What happens?
Instead of the specified relative movement, the axis makes an additional revolution.
 
When does this behaviour occur?
The Relative_TP mode is used for profile switch-over. The touch-probe event occurs simultaneously with a modulo overflow of the axis.
 
Which products are affected?
L_TT1P_TablePositioning in the L_TT1P_TechnologyModules_LM library (from V3.15.0.32)
Short-term measures:
There is no applicative short-term measure available.
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700296/1/