L_TT1P_TablePositioning: xPositioningDone and xDone are not set (corrected from V3.15.0)

Corrected from:
L_TT1P_TechnologyModules_LM (V3.15.0.32)
 
Response of the new version: 
The xPositioningDone bit is set for one cycle even if positioning is only activated via an edge.
 
What happens?
The xPositioningDone status bit is never set to TRUE. The xDriveInTarget bit is set. After completion of positioning, xPositioningActive is reset.
 
When does this behaviour occur?
Positioning is started via an edge at xExecute. xExecute does not remain TRUE until the end of positioning.
A previously aborted positioning process is started via an edge at xFinishPositioning. xExecute does not remain TRUE until the end of positioning.
 
Which products are affected?
L_TT1P_TablePositioningBase in the L_TT1P_TechnologyModules_LM library (V3.14.0.21 and higher)
 
Short-term measures:
Evaluate the status bits xPositioningActive and xDriveInTarget
 