L_TT1P_RegisterControlState: Error when TP occurs during mark correction

What happens?
The cuts no longer remain within mark control.
 
When does this behaviour occur?
The behaviour occurs when from a certain speed the next TP occurs during the correction movement of the previous TP. 
 
Which products are affected?
L_TT1P_RegisterControlState in the L_TT1P_TechnologyModules_LM library (V3.14.2.58 and higher)
 
Short-term measures:
Use the parameters lrUpperCorrPos, lrLowerCorrPos and shift the compensating movement such that it will already be completed when the next TP occurs.
 
Evaluation/recommendations:
If the above short-term measure is observed, the behaviour will be correct.
 
No change is planned for this behavior.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700178/1/
Kontaktformular