Exception when switching the variable declaration to the tabular view (corrected with V3.15)
Corrected from:
PLC Designer V3.15
Application Template Standard project template V3.15.02
Response of the new version:
The declaration can be easily switched to the tabular view.
What happens?
An exception occurs when switching the variable declaration to the tabular view:
Unhandled exception has occurred in your application.
Index was outside the bounds of the array.
When does this behaviour occur?
If the project is based on the L_FAST_Standard template (ApplicationTemplate Standard) and the variable declaration is switched to the tabular view in the MFB_MachineModuleName function block, an exception occurs.
Which products are affected?
PLC Designer V3.14
Application Template Standard project template V3.14
Short-term measures:
Only use the textual view of the variable declaration. This is the default setting.
Evaluation/recommendations:
Switching the variable declaration to the tabular view may lead to an exception. In most cases, the textual view is used for programming.