L_TT1P_CrossCutter: Access points are not documented (corrected from V3.13)

Corrected from:
L_TT1P_TechnologyModules_LM (V3.13.0.7)
 
Response of the new version:
The access points of the CrossCutter TM are documented in the online help for PLC Designer V3.13.
 
What happens?
The access points of the technology module (scAP) are not documented.
 
Which products are affected?
Documentation for the L_TT1P_CrossCutter technology module from the L_TT1P_TechnologyModules_LM library (V3.12.0.9 and higher)
 
Description of the access points:

AP01_xEndOfProfileWindowSize: Enable of the AP01_lrEndOfProfileWindowSize access point.

AP01_lrEndOfProfileWindowSize: The AP01_lrEndOfProfileWindowSize access point is used to define the window size for identifying the EndOfProfile. Within the window, only one EndOfProfile can be identified.

AP02_xOverspeedUpperLimit: Enable of the AP02_lrOverspeedUpperLimit access point.

AP02_lrOverspeedUpperLimit: Via the lrSetOverspeedScaled input you can define the factor for overspeed during the synchronous phase. Value range of the factor: -0.9 ... 2.0

The AP02_lrOverspeedUpperLimit access point can be used to freely select the upper value range limit.

Evaluation/recommendations:
The documentation for the access points is being revised.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201600104/1/