L_TT1P_RegisterControl: Mark error calculation is sporadically incorrect (eliminated from V3.13.1)

Eliminated from:
L_TT1P_TechnologyModules_LM (ab V3.13.1.25)
 
Behaviour of new version: 
The error does not occur anymore. All mark errors are calculated correctly.
 
 
What happens?
Sporadically, the calculated mark error is incorrect. In this case, the technology module performs an incorrect position correction for the corresponding mark.
 
When does this behaviour occur?
The Register Control technology module performs a position correction for the marks on a conveyor.
 
Which products are affected?
L_TT1P_RegisterControl function block from the L_TT1P_TechnologyModules_LM library (from V3.12.0.9)
 
Short-term measures:
Use library 3.10.x.x

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201600077/1/
Kontaktformular