L_TT1P_TablePositioningBase: Residual path traversing does not work correctly (corrected from V3.12)

 

 

 

 

Corrected from:
L_TT1P_TechnologyModules_LM V3.12.0.9
 
Response of the new version:
Profiles previously aborted via the xAbortPositioning input will be completed if the xFinishPositioning input is set after aborting the positioning process.
 
What happens?

A relative profile which has been previously aborted via the xAbortPositioning input is not completed correctly.

When does this behaviour occur?

1. xExecutePositioning = TRUE
2. xExecutePositioning = FALSE (i.e. only set for a short time to start the profile)
3. xAbortPositioning = TRUE
4. xAbortPositioning = FALSE
5. xFinishPositioning = TRUE
Which produts are affected?
L_TT1P_TablePositioningBase function block from the L_TT1P_TechnologyModules_LM library (V3.10.0.8 and higher)
 
Short-term measures:
If possible, use "absolute positioning".
  
Evaluation/recommendation: