L_TT1P_VirtualMaster, FlexCAM: Different behaviour of the 'Ramp_Pos' coupling mode (corrected from V3.12)

​Corrected from:
L_TT1P_TechnologyModules_LM library V3.12.0.9

Response of the new version: 
The behaviour of the coupling modes in the FlexCam and in the VirtualMasterHigh TM remains unchanged. The name of the coupling mode in the VirtualMasterHigh TM has been changed from Ramp_Pos to Ramp_Dist. Thus, the coupling mode in the VirtualMasterHigh TM has been provided with a clear name corresponding to the function (clutch-in over a parameterisable distance). 
                                                                                                                                                                

What happens?
The behaviour of the 'Ramp_Pos' coupling mode of the VirtualMaster TM and the behaviour of the 'Ramp_Pos' coupling mode of the FlexCam TM is different.

When does this behaviour occur?
 
Which products are affected?
L_TT1P_VirtualMaster and L_TT1P_FlexCAM function block from L_TT1P_TechnologyModules_LM library (V3.10.0.8 and higher)
 
Short-term measures:
Since the function of the coupling modes is not impaired, there is no short-term measure required.
  
Evaluation/recommendations:
The behaviour of the coupling modes is different although they have the same name. The coupling mode of the VirtualMaster TM works as a function of the distance and not as a function of the absolute positions. Therefore, the name of the coupling mode has been changed.
 