L_TT1P_RegisterControl: In the case of large following errors, the mark error is not calculated correctly (eliminated from V3.10)

Eliminated from:
L_TT1P_TechnologyModules_LM V3.10.0.8
 
Behaviour of new version:
The calculation of the mark error works correctly (independend from the following error of the TP axis).
 
 

What happens?
In the case of large following erros in the TP axis, the mark error is not calculated correctly. As a consequence, the mark correction does not work correctly.  

When does this behaviour occur?
The behaviour occurs if the following error of the touch-probe axis becomes too large (e.g. in the case of default controller settings). 
 
Which products are affected?
L_TT1P_RegisterControl function block in L_TT1P_TechnologyModules_LM library (V3.8 and higher)
 
Short-term measures:
Optimise the controller.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500066/1/
Kontaktformular