L_TT1P_ElectricalShaftPosBase: Measuring point MP03_lrSetGearBoxPosOut indicates the value 0

Eliminated from:
L_TT1P_TechnologyModules_SM3 V3.9.0.9
L_TT1P_TechnologyModules_LM V3.9.0.62
 
Behaviour of new version:
The measuring point MP03_lrSetGearBoxPosOut shows valid values.
 
What happens?
The MP03_lrSetGearBoxPosOut element of the scSignalFlow technology module output constantly indicates the value 0.
 
When does this behaviour occur?
When the L_TT1P_ElectricalShaftPosBase technology modules is activated (xEnable=TRUE), the measuring point MP03_lrSetGearBoxPosOut indicates the value 0.
 
Which products are affected?
PLC Designer from V3.8
L_TT1P_TechnologyModules V3.8.0.23

Short-term measures/recommendations:
If you want to access the information of the measuring point MP03_lrSetGearBoxPosOut in your application, use the L_TT1P_ElectricalShaftPosState or the L_TT1P_ElectricalShaftPosHigh technology module.
 
Evaluation:
The measuring point MP03_lrSetGearBoxPosOut indicates the value 0. The function restriction does not impair the actual function of the technology module. The function restriction only concerns the L_TT1P_ElectricalShaftPosBase technology module.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400219/1/