L_SMC_Multiturn: Error message SMC_DI_LINEAR_AXIS_OUTOFRANGE (no correction planned)

Corrected from:
Library:  L_SM3_DriveUtil   (no correction planned)
Response of the new version: 
(no correction planned)

  
What happens?
The SoftMotion drive indicates the error message:
SMC_DI_LINEAR_AXIS_OUTOFRANGE
 
When does this behaviour occur?
The above SoftMotion error message may occur when the controller is restarted and the L_SMC_Multiturn function block is used in the project.
 
Which products are affected?
Library: L_SM3_DriveUtil  V3.6 and higher
 
Short-term measures:
Call the MC_Reset function block (SM3_Basic library) in the PLC project to reset the error message. After this, the Motion axis can be normally traversed.
 
Evaluation/recommendations:
When using the L_SMC_Multiturn FB, the SoftMotion may indicate an error when the controller is restarted. The error message can be reset by using the MC_Reset FB.