ApplicationTemplate: Frame for module visualisation cannot be selected (eliminated from V3.5.1)

Eliminated from:
PLC Designer V3.5.1
Application Template V3.5.1

Behaviour of the new version:
The order of the two frames of the L_Main visualisation was changed to ensure that the right frame for selecting the module visualisations will be selected when clicking L_Main.



What happens?
The L_Main visualisation has got two frames. To change in L_Main between the visualisations of the planned modules, you have to select the module visualisations in the frame selection of the 'GenElemInst_8' frame. Every time this frame is clicked, the 'fraTopMaster' frame is selected.

When does the problem occur?
The 'GenElemInst_8' frame is superimposed by the 'fraTopMaster' frame and completely covered by it.

Which products are affected?
PLC Designer V3.3 and higher
Application Template V3.3 and higher

Diagnostics options:
None

Short-term measures/recommendations:
Open the element list (menu Visualisation>Element List) of the L_Main visualisation and select the 'GenElemInst_8' frame. Then open the frame selection dialog (menu Visualisation>Frame Selection) and select the module visualisations.

Evaluation:
It is not posible to open the right frame to insert the module visualisations into the main visualisation by clicking the L_Main visualisation.