"Slave not found" system error after deleting a machine module instance (corrected from V3.17)

Corrected from:
PLC Designer V3.17
Standard ApplicationTemplate project template V3.17
 
Response of the new version:
Deleting a machine module instance triggers no system error.
 
What happens?
The ApplicationTemplate indicates the following system error in the 'L_Main' visualisation:
Slave not found 
 
When does this behaviour occur?
The 'Slave not found' system error may occur after deleting a machine module instance with the Delete Machine Module References context menu command from the PLC project.
 
Which products are affected?
PLC Designer V3.13
Standard ApplicationTemplate project template V3.13
 
Short-term measures:
Update the ACD communication channel after deleting a machine module instance. For this, right-click on the A70_MachineModuleSources folder to open the context menu and execute the Create ACD Slave Access menu command.
 
Evaluation/recommendations:
When deleting a machine module instance, the ACD communication channel is not updated. This leads to a system error when executing the ApplicationTemplate. The function restriction is recognised immediately after downoloading the project.