L_TT1P_TablePositioning: Incorrect behaviour of xDone after completing a profile with xFinishPositioning (corrected from V3.12)

Corrected from:
L_TT1P_TechnologyModules_LM V3.12.0.9
 
Response of the new version:
If a positioning process is completed with xFinish, the xDone output will be set to TRUE for one cycle if the xFinishPositioning input has already changed to FALSE again. If xFinishPositioning is still TRUE after positioning has been completed, the xDone output will remain set until xFinishPositioning is set to FALSE again.
 
 

What happens?
The xPositioningDone and xDone outputs are not set to TRUE.

When does this behaviour occur?
The behaviour occurs if a positioning process which has been previously aborted is completed with xFinishPositioning.
 
Which produts are affected?
L_TT1P_TablePositioningBase function block from the L_TT1P_TechnologyModules_LM library (V3.10.0.8 and higher)
 
Short-term measures:
None
 
Evaluation/recommendation: