L_TT1P_RegisterControlState: Incorrect correcting motion (eliminated from V3.13)

Eliminated from:
L_TT1P_TechnologyModules_LM (ab V3.13.0.7)
 
Behaviour of new version:
The correction process for the technology module Register Control is always terminated without jump.
 
 
What happens?
The correction process for position correction of the RegisterControl technology module is completed with a jump.
 
When does this behaviour occur?
The behaviour occurs always. Since the not corrected position differences are adding up, the error mainly shows effect when using a mark stack.
 
Which products are affected?
L_TT1P_RegisterControlState function block from the L_TT1P_TechnologyModules_LM library (V3.12.0.9 and higher)
 
Short-term measures:
If possible, do not use the mark stack in this technology module version.
As an alternative, you can use an earlier technology module version.
 
Evaluation/recommendations:
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201600131/1/