L_MC2P: MC_GearIn, MC_GearInPos do not work properly with modulo values in decimal (corrected from V03.20.00)

Corrected from:
Library:   L_MC2P_MotionControlCam  (FAST Motion)  from V03.20.00.10 
                      (Update via Package-Manager)
 
Response of the new version: 

The target position of the slave axis is now correctly reset to position 0 each time the parameterized slave clock length is exceeded.


What happens? 

The target position of the slave axis incorrectly jumps back to position 0 depending on the master clock.


When does the behaviour occur? 

FBs MC_GearIn, MC_GearInPos: The behaviour occurs with certain combinations of master clock length, slave clock length and master-slave gear factor:
  • Each time the amount of the difference between the slave clock length and the multiple of the normalized master clock length is less than 1/(2^31).
  • Rarely, if the slave clock length is exactly the multiple of the normalized master clock length.
Which products are affected?
Library:  L_MC2P_MotionControlCam  (FAST Motion)
 
Short-term measures, Evaluation / Recommendations:
none