Function extension:
Application synchronization via digital input;
The application in the i950 can now also be synchronized with other devices via an external signal source and a digital input from the inverter.
Contained in the following products;
Servo inverter i950 FW: from V01.14.00
Application
Synchronization of multiple inverters via an external synchronization source underusing the digital inputs of the inverters.
Related parameters:
0x2581:001 (Application synchronizationSync source), zadditionally selectable:
- 20 : Digital input 1
- 21 : Digital input 2
- 22 : Digital input 3
- 23 : Digital input 4
0x2630:10..13 (Digital input: Sync settings)
Settings for synchronization via digital input, aanalogous to the settings for synchronization via CANopen under 0x2301:10..13:
Exampletopology with synchronization via digital input;

[Automatic Translation]