Faulty status message with active STO (corrected from V3.32.0)

Fixed from:
Libraries:
L_TB2P_TechModulesBasic (from V3.32.0)
L_TF2P_TechModulesFollowingPositioning (from V3.32.0)
L_TS2P_TechModulesSynchronisingCamming (from V3.32.0)
L_TW2P_TechModulesWindingTraversing (from V3.32.0)
(Update via Easy Package Manager)
Behaviour of the new version:
The error message eErrorID = DriveSTOActive can be acknowledged with xResetError. The TM displays the warning as long as the STO is active.

Description of the behavior:

The technology module (TM) reports the error message xError = TRUE with the eErrorID = DriveSTOActive. The error message cannot be acknowledged.


Conditions under which the behavior occurs:

  • STO is activated (yellow terminal). The xResetError = TRUE means that the error message is not acknowledged.
Alternative
  • STO is activated (yellow terminal). By parameter 107 = warning[2] the error message is more deactivet.

 
Affected products:

Libraries: 
L_TB2P_TechModulesBasic 
L_TF2P_TechModulesFollowingPositioning
L_TS2P_TechModulesSynchronizingCamming 
L_TW2P_TechModulesWindingTraversing

Short-term measures, recommendations,evaluation:

After the STO is no longer present at the yellow terminal, the error can be acknowledged via xResetError. The reported behavior is an error in the technology module. The error message or warning should be displayed depending on the parameterization of the  parameter 107   will be reported. If the error message is deactivated via the parameter, no error message should be reported on the TM 

[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202400141/1/