L_TT1P_ElectricalShaftVel: In the event of an error (xError), xSynchronized remains set.

What happens?
The status access reports xSynchronized = TRUE, although the TM is in error state eTMState = ERROR.

When does the behaviour occur?
Before the state eTMState = ERROR, the TM was synchronised with the conductance.

Which products are affected?
Function module L_TT1P_ElectricalShaftVel from library L_TT1P_TechnologyModules_LM

Short-term measures:
The status output should only be evaluated in the state eTMState unequal ERROR.

Evaluation / recommendations:
The status is frozen in the event of an error. As soon as the error state is exited, the status xSynchronized = FALSE is updated.
The synchronous operation function is not affected by the status. It is recommended to also consider the status of the TM (eTMState) for the evaluation of the status signal xSynchronized.

Note:
No change is planned for this behaviour.