i550: Parameter set download if required

Function extension:
When the boot application is started in the Lenze controller (e.g. when the controller is switched on), the controller only loads the parameter sets into the i550 frequency inverters connected via EtherCAT if the parameter set of the drive differs from the parameter set stored in the controller for this i550. After a successful parameter set download, the controller stores the parameter set in the i550 in a power failure-proof manner.

Included in which products?
Cabinet Controller c300 as of V3.18
Cabinet Controller 3200C as of V3.18
Cabinet controller c520 as of V1.3
Cabinet controller c550 V1.3 and higher
Cabinet controller c750 as of V1.3.1
Panel Controller p300 V3.18 and higher
Panel controller p500 as of V3.18

Frequency Inverter i550 as of V5.4

Application:
When switching on, the Lenze controller checks whether the configured firmware and the configured parameter set are stored in the i550 connected via EtherCAT. If this is not the case (e.g. after a device exchange), the controller carries out the corresponding download. Due to this function extension, the controller no longer has to load the parameter sets into the i550 each time it is switched on. This significantly reduces the start phase, depending on the number of connected i550s.

To be able to use the function extension, the device descriptions suitable for the devices listed above must be inserted in the PLC Designer project.