Initialising the brake resistor utilisation

Function extension:
The "Initial value brake resistor overload" parameter C00122/2 can be used to select an initialisation value for the I2*t utilisation of the brake resistor (C00133).


Contained in which products?

  • Inverter Drives 8400 StateLine V21.00.00
  • Inverter Drives 8400 HighLine V21.00.00
  • Inverter Drives 8400 TopLine V21.00.00

Application:
So far, the thermal brake resistor model has been initialised with 20°C when switching the mains for a hot brake resistor. With the "Initial value brake resistor overload" parameter C00122/2, you can select a new initialisation value.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201900249/1/