L_TF2P_TablePositioningBase: Positioning cannot be continued in velocity positioning mode (2) (eliminated from V3.22.0)

Corrected from:
Library:  L_TF2P_TechModulesFollowingPositioning from V3.22.0.26
                      (Update via EASY Package-Manager)

Response of the new version:
L_TF2P_TablePositioningBase:
If a profile is aborted in ePositioningMode = Velocity with STO, then it can be restarted with xFinishPositioning.

What happens?
L_TF2P_TablePositioningBase:
If a profile is aborted in ePositioningMode = Velocity with STO, then it cannot be restarted with xFinishPositioning.
 
When does the behaviour occur?
The profile in ePositioningMode = Velocity is aborted with STO.

Which products are affected?
Function block L_TF2P_TablePositioningBase from library L_TF2P_TechModulesFollowingPositioning
 
Short-term measures, Evaluation, Recommendations:
Restart the profile in ePositioningMode = Velocity with xExecutePositioning.