PLC Designer and Easy-Export: Missing PDO's in the device description (no change intended)

Corrected from:
Servo-Inverter i950 FW:      (no change intended)
 
Response of the new version:
The described behaviour is known.
Standard technology applications (TAs) require 8 double words per transmission direction, which is why Lenze has provided 8 double words for the EASY export function by default.
 
 
What happens?
The EASY export function uses a standard mapping with 8 double words per transmission direction for the process data. However, the fieldbus module supports up to 16 double words per transmission direction, which are also displayed as fieldbus nodes with the i950 target in PLC Designer.
This means that the PDO images do not match. Under a Lenze controller (e.g. 3200C) there are only 8 inputs and 8 outputs.

 
When does the behaviour occur?
Use of the EASY-Export function from PLC-Designer to create the device application files (*.lda; *lfl).
 
Which products are affected?
Servo-Inverter i950 FW
 
Short-term measures, Evaluation/Recommendations:
The mapping of the i950 target inserted under a Lenze controller must be extended manually in the "Process Data" tab if necessary.
 