Corrected from:
Servo inverter i950 FW: from V01.03.07.1252
Response of the new version: A preset safety password is transferred to the servo inverter during project download via Application Loader.
No errors are reported if the correct safety password is entered.
What happens?
When parameterizing an offline device, a download password can be assigned for the safe parameter set. This password is transferred to the servo inverter during the project download with the Application Loader if no errors occur.
In online mode, the download password is requested when modifying the safe parameter set or accessing the safe parameters.
In the event of an error the download password is not transferred and the user cannot modify the safe parameter set and load it into the device. The error "Password check failed" is reported.
When does the behaviour occur?
Prepared project files (lda files) can be transferred to the servo inverter with the application loader. With an i950ES servo inverter in version 01.02.xx.xxxx the safety password is not transferred when transferring a project file.
Which products are affected?
Servo inverter i950 FW
Short-term measures, Evaluation , Recommendations:
The user must log in using the default password, or the password file must first be created using the "Reset secure parameter set" command before a new password can be assigned for the secure parameter set.
Notes on assigning the download password are also described in the online help in the chapter "Engineering Tools / Common Tools / Safety Parameter List".
Automatic Translation