L_MC1P_BrakeTest: Twice the torque is erroneously applied to the brake (corrected from V03.17.00)

Corrected from:
Library:  L_MC1P_MotionControlBasic  (FAST Motion) V03.17.00.226
                      (update via Package Manager)
Response of the new version:
The described faulty torque behaviour of L_MC1P_BrakeTest, when a negative motor torque is selected, has been corrected now.
 
What happens?
When a negative motor torque is selected, the L_MC1P_BrakeTest does not work correctly.
After the hold time 'lrHoldTime', the torque is not reduced to zero, but to twice the negative value.
Example: FB_BrakeTest.lrMotorTorque := -0.5 Nm. ==> After the hold time 'lrHoldTime', the torque amounts to -1.0 Nm.
 
When does this behaviour occur?
The behaviour occurs if a negative motor torque 'lrMotorTorque' is selected.
 
Which products are affected?
Library:  L_MC1P_MotionControlBasic  (FAST Motion)

Short-term measures:
 
Evaluation/recommendations:
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700359/1/