L_TT1P_TablePositioningBase: Profile cannot be started after aborting positioning (corrected from V3.14.1)

Corrected from:
L_TT1P_TechnologyModules_LM (V3.14.1.50)
 
Response of the new version:  
The first FALSE->TRUE transition after an aborted positioning process starts a new positioning process.  
 
 
What happens?
No new positioning process is executed. A new positioning process only starts after a new FALSE->TRUE transition.
 
When does this behaviour occur?
After positioning in the velocity mode (ePositioningMode = 4, Velocity), the current profile is aborted via the xAbortPositioning input. After this, the xExecutePositioning input is set again.
The technology module immediately changes to the "Ready" state while the profile is being aborted.
 
Which products are affected?
L_TT1P_TablePositioningBase from the L_TT1P_TechnologyModules_LM library (from V3.14.0.21)
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700010/1/