L_MC1P: Virtual axis in the modulo measuring system: When positioning to the zero point, the exact target is not always reached (corrected from V3.14.1)

Corrected from:
Library:   L_MC1P_MotionControlBasic (FAST Motion) V03.14.01.01
                 (update via package manager)
 
Response of the new version:
The target position always will be reached exactly now.
 
 
What happens?
When positioning to the zero point, the exact target position is not always reached.
Depending on the selected task time, the axis stops just before or just behind the zero point.
 
When does this behaviour occur?
Virtual axis in the modulo measuring system and absolute positioning to zero.
 
Which products are affected?
Library:   L_MC1P_MotionControlBasic  (FAST Motion)
                 (contained in the PLC Designer)
 
Short-term measures:
None.
 
Evaluation/recommendations:

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201600281/1/
Kontaktformular