L_MC1P - MC_MoveVelocity: '0' setpoint speed leads to 'Arithmetic error' error message (corrected from V3.13.0)

Corrected from:
Library:  L_MC1P_MotionControlBasic (FAST Motion)  from V03.13.00.38
               (contained in PLC Designer from V03.13.00)
 
Response of the new version:
If setpoint speed = 0 is selected at the 'MC_MoveVelocity' FB, no error message appears anymore. 
 
What happens? 
If setpoint speed = 0 is selected at the 'MC_MoveVelocity' FB, the 'Arithmetic error' error message appears.
 
When does this behaviour occur?
The behaviour occurs when using axes with limited traversing range and
the SW limit position monitoring function is activated. 
 
Which products are affected?
Library:  L_MC1P_MotionControlBasic (FAST Motion)
               (contained in the PLC Designer)
 
Short-term measures:
Do not select '0' setpoint speed at the MC_MoveVelocity FB.
If required, use the speed override to come to standstill by means of override = 0.
 
Evaluation/recommendations:
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500881/1/
Kontaktformular