L_MC1P: Motor rotation indication: Following error monitoring function responds (corrected from V03.17.00)

Corrected from:
Library: L_MC1P_MotionControlBasic (FAST Motion) V03.17.00.226
              (update via Package-Manager)

Response of the new version:
The following error monitoring function of the control system will not be actuated in the corresponding motion axis in the case described below.

 
What happens?
When using the "Motor rotation indication" commissioning function of the i700 (manual control), the following error monitoring function of the control system may be actuated in the corresponding motion axis.
The actuation of the following error monitoring function has no effect on the "Motor rotation indication" function and the indicated error message can be reset.

When does this behaviour occur?
The behaviour occurs if the executed movement is larger than the permissible following error tolerance set in the control system.
 
Which products are affected?
Library: L_MC1P_MotionControlBasic (FAST Motion)
 
Short-term measures:
If necessary, reset the indicated error message after completion of the motor rotation indication.
 
Evaluation/recommendations:
The 'Motor rotation indication' function can be executed despite actuation of the following error monitoring function.  
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500831/1/