L_TT1P_Winder: Torque is not read out (corrected from V3.9.0)

Corrected from:
L_TT1P_TechnologyModules_SM3 library V03.09.00.9

Response of the new version: 
The described function restriction no longer occurs.
                                                                                                                                                                

What happens?
The following functions are not provided.
-    Identification of the friction
-    Identification of the moment of inertia
-    Torque display in the Winder technology module

When does this behaviour occur?
The behaviour occurs if the function block is used in an application with the SM3_Basic library on V3.5.3.xx.

Which products are affected?
L_TT1P_WinderDancerCtrl and L_TT1P_WinderTensionCtrl function blocks from L_TT1P_TechnologyModules_SM3 library (V3.8.1.25 and higher)

Short-term measures:
Use the placeholder resolution of the PLC Designer and select the SM3_Basic library on V3.5.2.21.

Evaluation/recommendations:
When observing the above short-term measure, the functions can be used without restrictions. Regardless of the SM3_Basic library version, the error has been removed in L_TT1P_TechnologyModules library V3.9.0.9 and higher.