L_TT1P_ElectricalShaftPos: Measuring point MP04_lrSetClutchPos is not valid if TM is not coupled to master axis (xSyncPos=FALSE) (corrected from V3.10.0)

Eliminated from:
Library:   L_TT1P_TechnologyModules_SM3   (L-force Motion)  from V03.10.00.07
                (contained in PLC designer from V03.10.00)
 
Behaviour of new version:
The measuring point "MP04_lrSetClutchPos" always indicates valid values when the TM is enabled (xEnable = TRUE).
 
 

What happens?
Technology module  'L_TT1P_ElectricalShaftPos':  The measuring point "MP04_lrSetClutchPos" displays invalid values. 

When does this behaviour occur?
The values of the measuring point "MP04_lrSetClutchPos" are invalid, if the TM is not coupled to the master axis (xSyncPos = FALSE). 
 
Which products are affected?
Library:   L_TT1P_TechnologyModules_SM3   (L-force Motion) 
                (contained in PLC designer)
 
Short-term measures:
The measuring point "MP04_lrSetClutchPos" can be calculated from the other measuring points of the scSignalFlow structure:
MP04_lrSetClutchPos = MP03_lrSetGearBoxPosOut + OP03_lrOffsetTotal.
 
Evaluation/recommendations:  
If the above short-term measure is observed, the measuring point can be calculated. The functionality is thus provided.
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500248/1/