Corrected from:
- i700 servo inverter V01.09.03.10964
Response of the new version:
When executing a commissioning function the status bits will be set corectly, now.
What happens?
When executing a commissioning function, under 'Identification: Status word' (0x2832/0x3032), sporadically, the 'Enabled' status bit will be erroneously set in addition to the other bits.
When does this behaviour occur?
After successful execution of an identification function, the 'Finished' status (bit 2 = 1) will be displayed in the status word. Or 'Failed' (bit 3 = 1), in the case of a faulty execution.
Sporadically, it may, however, happen that the 'Enabled' status bit will be set in addition.
Setting the 'Enabled' status bit has, however, no influence on the 'Finished' and 'Failed' status bits. They are used correctly.
Which products are affected?
- i700 servo inverter
Short-term measures:
None.
Evaluation/recommendations:
If necessary, ignore the additionally set 'Enabled' status bit.