i700 and I/O 1000 bus coupler parameters are not updated

What happens?
The parameters of the i700 servo inverter and the I/O 1000 EPM-S110 and EPM-S130 bus coupler are no longer updated in the PLC Designer (the parameters are no longer displayed with a yellow background).

When does the problem occur?
The above-described reaction occurs if Reset (cold) or Reset (original) are extremely often repeatedly executed with subsequent PLC start and the 'Parameters' tab of the above devices is open.

Which products are affected?
3200 C controller from V3.3
p500 panel controller from V3.3
i700 servo inverter
EPM-S110 (I/O1000 CANopen bus coupler)
EPM-S130 (I/O1000 EtherCAT bus coupler)

Diagnostics options:
None

Short-term measures/recommendations:
Create a boot project and restart the controller.

Evaluation:
After frequent Reset (cold) or Reset (original) with subsequent PLC start, it may happen that the PLC Designer will no longer update the parameters of the above devices.