L_SM3_DriveUtil - L_SMC_AxisBasicControl: Homing mode cannot be left by quick stop (corrected from V3.6.0)

Corrected from: 
Library:  L_SM3_DriveUtil (L-force Motion) V03.06.00.175
                       (contained in the PLC Designer from V03.06.00)
 
Response of the new version:
The ABC block can be used to stop homing via quick stop.
The drive brakes to standstill. After this, a new homing process can be started.

 
What happens?
The eAxisState output of the L_SMC_AxisBasicControl function block freezes in the 'homing' state.

When does this function restriction occur?
If the L_SMC_AxisBasicControl function block triggers a homing run and quick stop (QSP) is activated during homing, the function block permanently outputs 'Homing' at the eAxisState output.

Which products are affected?
Library:  L_SM3_DriveUtil (L-force Motion)
                      (contained in the PLC Designer)

Short-term measures/recommendations: 
Set the xDriveStart and the xRegulatorOn input to FALSE and back to TRUE again to reset the state of the eAxisState output.

Evaluation:
If quick stop is activated during homing, the state at the eAxisState output of the L_SMC_AxisBasicControl FB freezes.
 