Setting of the magnetisation (8400 HighLine from V10.0, TopLine from V01.10)

Function extension
In the ServoControl motor operating mode, the condition for completing magnetisation can now be set via code C0918. So far, (like also the present default setting), the magnetisation is completed when the magnetising current exceeds 87 % of the rated magnetising current (C0095). This threshold can be set in the range of 0 to 90 %. If the threshold is reduced, the magnetising time until the motor starts is shortened, but the torque with which the motor starts is lower.

Which products are concerned?
8400 HighLine with firmware from V10.00
8400 TopLine with firmware from V01.10

Applications
After controller enable a quicker start-up of the drive can be achieved. If the objective is to start immediately after controller enable without the full torque is required.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201109683/1/
Kontaktformular