Fail-QSP fault response added to brake relay monitoring (C0602=4) (as of OPERATING SYSTEM V8.3)

Function extension:
The fault response for brake relay monitoring can now also be set to Fail-QSP under C0602. Previously, only 'Off' or 'Trip' were available for selection.
For lifting applications in particular, the advantage of using the Fail-QSP fault response is that the controller remains enabled and the load can be kept active, whereas in the case of the 'Trip' fault response, the controller is inhibited immediately.

Note:
The new selection C0602=4 is not implemented in the current *.pdb device description files for GDC and DDS. Therefore, this new function is not supported by the GDC and DDS PC tools.
Workaround:
Entry via keypad, write selection C0602 = 4 using L_ParWrite() or via interface.

Included in which products/versions?
ECS Application OPERATING SYSTEM as of V8.3

Published with Service Message No. 2010/32
CR Id: LDS00024919, Failure Report Id: 8748