Eliminated from:
EtherCAT E94AYCET FV 2.00 communication module
Behaviour of the new version?
All data types (BYTE, WORD, DINT, etc.) are processed correctly.
What is the reaction?
The process data from the module to the master do not receive the correct values.
When does the problem occur?
Using the Engineer to map output ports of the BYTE data type results in different process data contents between module and master.
Which products are affected?
EtherCAT E94AYCET FV 1.01 communication module
Diagnostics options?
The above-described behaviour occurs if the master receives wrong process data.
Short-term measures/recommendations?
Do not use any ports of the BYTE data type.