Parameter C3012/0 (acceleration time) has no effect

Which products are affected?
ESPLV11XA0FC1 (Prepared Solution Flying Saw V1.1)

What happens?
The acceleration time of the flying saw is set in ms under code C3012. The acceleration time covers the time from starting out of standstill until achieving synchronicity. In version 1.1 parameter C3012 has no effect on the acceleration time which can thus not be changed via code C3012.

When does the problem occur?
The problem occurs when the Prepared Solution V1.1 is used. Parameter C3012 has not impact on the acceleration time of the flying saw.

Possible diagnostics?
None.

Short-term measures/recommendations?
Exchange of the following files:
- 'FlyingSawControlV010100.lib' and
- binary file for the target systems 'ECSxA' and 'ServoPLC'

Evaluation:
Parameter C3012 (acceleration time) is initialised with 1000ms. An impermissible high acceleration is not to be expected.