Additional CANopen objects as of 1000h (V3.0 onwards)

Which products are affected?
ECS power supply module ECSxE series, operating software V3.0

Function description
For the communication of the ECS power supply module with master control via CAN (like e.g. the CPC2000 by Lenze-Digitec) the CANopen objects with indices as of 1000h and higher need to be supported in order to ensure that the ECS power supply module connected to the CAN bus is detected.
Therefore, further CANopen objects ranging from 1000h to 1A01h have been implemented into the ECS power supply module. Regarding this, please note that these new objects can only be read (Read), i. e. it is impossible to make settings (see attachment below).

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200704181/1/