Implementation of different reset types

Which products are affected?

EVS93xx-EI (Servo PLC Version 6.3 DSMC control board)
EVS93xx-ET (Servo PLC Version 6.3 DSMC control board)
EPL-10200-EI (Drive PLC Version 6.3)

Function description

It is possible to activate different types of reset with the Drive PLC Developer Studio version 2.0:

1. Reset
Same performance as usual:
  • Variable are reset to their initialisation value or to zero if they do not have an initialisation value.
  • Retain variables and persistent variables remain unchanged.

2. Reset (cold)
Performance as described under 'Reset' but with the following extension:
  • Retain variables are set to zero or to their initialisation value.

3. Reset (original)
  • Retain variables and persistent variables are set to zero or to their initialisation value.
  • Data memories and program memories are deleted.
  • Default setting of the system codes is loaded.

Applications

Thanks to the different reset types it is possible to reset the different variable classes according to the respective requirements.