Cam switchover in function block CURVEC1

Application
  • Addition of two cams which, for example, have to be selected according to the product
  • Cam overlay for special positioning procedures

Description

Cam switchover in function block CURVEC1 by access to code C1310/0 can be performed with the controller disabled as previously. In addition, there is now the option of performing cam switchover during operation provided input CURVEC1-XRESET is set.

To prevent data inconsistency during the cam change -XRESET must be on a High signal until output -CAM-SEL-BUSY returns to Low (approx. 50 ms). Cam switchover without RSP or -XRESET = high will be rejected by the controller.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20010126/1/