Using axis data in different tasks

Question:
9400 HighLine servo controllers provide different tasks (two interval tasks and one cyclic task) for user program processing. If a measuring system has been defined in a task (e. g. system variable DI_AxisData in the application task), it may happen that the measuring system data need to be accessed in a different task (e. g. in the idle task for lower-priority position conversions between application units and incremental values). How can measuring system data be accessed in different tasks?

Answer:
In general, a measuring system shall only be defined at one location in the user program. To allow other tasks to use this measuring system, proceed as follows:
  • Declare a global DWORD variable.
  • Insert the variable with an input into the task in which the measuring system is generated. Assign the measuring system to the variable (e. g. system variable DI_AxisData).
  • Insert the variable with an output into the task in which the measuring system is required. Connect the variable to the required function block.


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200801673/1/