Interrupt and input/output address for LPT1 can be modified via system bus configuration tool

Question:

Is it possible to set an interrupt for the CAN communication via the parallel port (LPT1) different to the default interrupt 7?

Answer:

Yes, with the Lenze software configuration tool the interrupt for the CAN communication can be modified via the parallel port (LPT 1) by the EMF 2173 IB PC system bus adapter for all Lenze PC programs using a CAN communication (e. g. Global Drive Control GDC). This information can be taken from the device manager of your Windows operating system.

In case of GDC the interrupt can be modified from version 4.6 on. If you have an older version, please use interrupt 7.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200401174/1/